3. Operation of CON Related Controllers
93
3.16.4 Load Cell Inactivation
Function of the loadcell can be invalidated temporarily on an actuator equipped with a loadcell.
(SCON-CB)
Touch [Load cell inactivation] in Other setting screen, and the controller gets rebooted and the
loadcell becomes invalid.
Caution: There will be no confirmation window appearance after touching [Load cell inactivation]
button.
Loadcell becomes valid at reboot of the next controller or when the power is back on.
3.16.5 I/O Customizing
I/O customizing becomes available if PIO pattern is set to “5: User Select Mode] in PCON-CYB,
ACON-CYB and DCON-CYB.
Select a desired number of the positions (4, 8, 16, 32 or 64), and necessary number of command
position number signals (PC*) and the start signal CSTR should be assigned to the input ports, and
necessary number of complete position number signals (PM*) and the positioning complete signal
PEND to the output ports. Desired signals from the indicated signals (refer to Signals Available for
Assignment) can be assigned to the other ports.
Touch [I/O Customizing] in Other Setting window to show the I/O customizing window.
(It is set to the initial assignment condition as shown in the
table below at delivery.)
Select a number of positions.
In accordance with the selected number of positions,
necessary signals should be assigned to the input and
output ports.
A pulldown button ▼ button should be displayed to a port
available for signal assignment.
Touch the pulldown ▼ button and select a signal to be
assigned.
Once all the necessary items are selected, touch [OK] to
confirm the assignment.
The number of positioning points will be changed and the
input and output signals will become valid after a reboot.