6. Operation of ELECYLINDER
332
6.6.1 Monitor Screen
Touch [Production info] and the production information screen will be displayed. [Refer to 6.14]
Touch [Maint.] and the maintenance information screen will be displayed. [Refer to 6.6.2]
[Displayed Items]
Input signals The status of each input signal is shown. ON is lit. OFF is unlit.
Output signals The status of each output signal is shown. ON is lit. OFF is unlit.
Cur. pos. The current position is shown.
Cur. vel. The current speed is shown.
Cycle time The cycle time calculated from the velocity and acceleration /
deceleration set for the way forth and the way back is shown.
Cur. ratio The command value of electrical current is shown as a percentage of
the rated current.
Overload level The overload level is shown in the rate that the motor raising
temperature assumed to generate the overload alarm set as 100%.
PCB temp. Temperature of the control PC board in the actuator is shown.
Alarm code The applicable alarm code is shown.
Actuator S/N Shows the manufacturing number of the actuator.