4. Operation of SEP Related Controllers
215
3) Jog (Use the arrow keys [Jog-] and [Jog+] to jog the actuator to the target position and then
acquire the achieved position (current position) as the forward end position or backward end
position).
An example of operation mode 0 (standard movement between 2 points) is explained.
How to acquire the current position, 80.0 mm, as the backward end position is explained.
No. Operation Screen Remarks
1 Touch [Pos. Edit] on the SEP
menu screen.
2 If the position data edit
password is other than
“0000,” the password input
screen appears.
Input a position data edit
password and touch [ENT].
You can set a position data
edit password from “Position
edit password” on the
parameter edit screen.
3 Set the position, acceleration
and deceleration relating to
the backward end position.
Touch [Backward Position].
Touch [Menu] to return to the
SEP menu screen.
4 Touch [Jog].
Touch [Menu] to return to the
position setting screen.
* Perform home return if not
already completed.
5 If the servo is off, touch [SV
ON] to turn on the servo.
6 Touch [Chg Vel] to set a
desired jog speed.