4. Operation of SEP Related Controllers
220
5) Setting of push-motion operation (push power, push band)
An example of operation mode 0 (standard movement between 2 points) is explained.
An example of push-motion operation at the backward end is explained.
Push power: 50%, push band: 5.0 mm
No. Operation Screen Remarks
1 On the SEP menu screen:
Touch [Pos.Edit].
2 If the position data edit
password is other than
“0000,” the password input
screen appears.
Input a position data edit
password and touch [ENT].
You can set a position data
edit password from “Position
edit password” on the
parameter edit screen.
3 Set the position, acceleration
and deceleration relating to
the backward end position.
Touch [Backward Position].
Touch [Menu] to return to the
SEP menu screen.
4 Touch the value in
[PushPower].
The numeric keypad appears.
Touch [5] and [0], and
touch [ENT].
Touch [Menu] to return to the
position setting screen.
5 50 is shown in PushPower.
Touch [Menu] to return to the
position setting screen.
6 Touch the value in
[PushBand].
The numeric keypad appears.
Touch [5], and
touch [ENT].
Touch [Menu] to return to the
position setting screen.