4. Operation of SEP Related Controllers
222
6) Setting of ecology function (automatic servo OFF function)
An example of operation mode 0 (standard) is explained.
How to turn off the servo automatically 5.0 seconds after stopping is explained.
No. Operation Screen Remarks
1 On the SEP menu screen:
Touch [Initial Set].
2 Set a desired automatic
servo OFF delay time.
Touch [Parameter].
3 If the system password is
other than “0000,” the
password input screen
appears.
Input a system password and
touch [ENT].
The default system password
is “5119”.
For how to change the
system password, refer to
4.12, “Parameters [Change
System Password].”
4 Touch [Edit Parameter].
5
Touch [] and [] to navigate
through the screens until the
one for setting the automatic
servo OFF delay time is
displayed.
6 Touch the value of automatic
servo OFF delay time.
The numeric keypad
appears.
Touch [5], and
touch [ENT].

Table of Contents