12. Press the «Enter» key.
The setting is applied.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
6 Compressor clock
Menu
·········
01 Mon-Fri 06:30AM on
Switching point 01 is set
02 Mon-Fri 12:00PM off
Switching point 02 is set
03 Mon-Fri 01:00PM on
Switching point 03 is set
04 Mon-Thu 05:00PM off
Switching point 04 is set
05 Fri 03:00PM off
Switching point 05 is set
13. Press the «Right» arrow.
14. Press «Enter».
The
on/off
indicator flashes.
15. Use «Up» or «Down» to set the Compressor On action.
16. Press «Enter».
The setting is applied.
The Compressor ON action is set for the first switching point.
17. Specify further switching points in the same manner.
Result Weekdays, time and the Compressor ON/Compressor OFF actions are set for all switching points
of the user-defined clock program.
8.5.1.3 Activating the «Timer control» key
1. Use «Up» or «Down» to select the
Key clock
line.
2. Press «Enter».
The check box
Key clock
flashes in the active line.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
6 Compressor clock
Menu
Key clock : ☑
Active line with activated check box
Reset : ☐
01 Mon-Fri 06:30AM on
Switching point 01:
02 Mon-Fri 12:00PM off
Switching point 02
03 Mon-Fri 01:00PM on
Switching point 03
3. Press the «Up» key.
The check box is activated.
4. Press «Enter».
The setting is applied.
5. Press «Escape» repeatedly to return to the main menu.
Result The «Time control» key is activated.
8 Initial Start-up
8.5 Configuring machine start and stop
94
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2 No.: 9_9450 13 USE

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet