3. Press «Enter».
The currently active operating mode
Remote mode
flashes.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.2.3 Load control
Menu
Local mode: pA/pB Cycle
Remote mode : loc.-load RC
Active line
------------------------------
▶1 pA/pB Clock
·········
pA/pB Cycle
4. Use «Up» or «Down» to set the
loc.-load RC
input.
5. Press «Enter».
The local/LOAD remote contact operating mode is set.
Assign an input for the local/LOAD remote contact for switching the pressure control
1. Use «Up» or «Down» to select the
loc.-load RC
line.
2. Press «Enter».
The
DI
display flashes.
8 8 p s i 0 8 : 1 5 A M 1 7 6 ° F
Header
5.2.3 Load control
Menu
pA/pB DO DOR1.03 ☐
No input assigned
Logic : +
·········
Load RC DI1.06 ok ☑
Logic : +
loc.-load RC DI1.07 ☑
Active line
3. Use «Up» or «Down» to select a new input for local/LOAD remote contact.
4. Press «Enter».
The input for local/LOAD remote contact is assigned.
8.10.6.3 Setting local operating mode pB
The
pB
nominal pressure is normally set for local operation.
➤ When setting the
pB
nominal pressure, bear in mind that, under certain circumstances,
more than one compressor may be operating in local mode (see section 8.4 for adjusting
the nominal pressure).
Precondition Password access level 2 is activated.
1. Open the 5.2.3
<Configuration – Pressure control – Load control>
menu.
2. Use «Up» or «Down» to select the
Local mode
line.
8 Initial Start-up
8.10 Configuring the machine for master control
142
User Manual Controller
SIGMA CONTROL 2 SCREW FLUID ≥5.1.2 No.: 9_9450 13 USE