Keysight N9915-90020 User’s Guide 543
Interference Analyzer (SA Mode) – Option 236
Record/Playback (SA Option)
To view and edit the maximum number of records
Just after opening or initiating a session...
—Press
Session Data
—Then
TraceRecordLimit <n> (n = Max number of traces that can be
recorded).
Clear All Records Empties that session of recorded traces. Learn more in
“Manage Sessions” on page 553.
FieldFox Setting Changes during Record and Playback
During Recording
When any of the following State settings are changed during recording, the
State counter is incremented (
“About State and User Tags” on page 544) and
the settings are saved to the Session file along with the first trace to be
recorded with the new setting. During playback, the trace and display
annotation will reflect the change on the screen.
State settings:
Refer to
Table 19-1 for a list of the applicable state settings for the SA option.
Table 19-1 Summary of SA State Settings
Option Settings
SA
Average Type
Detector(s)
External Gain
Frequency Range
Preamp On/Off
Resolution BW
RF Attenuation
Source Settings
Sweep Acquisition
Trigger Settings
Video BW
Zero Span Sweep Time