EasyManua.ls Logo

Keysight Technologies C Series - 12 Electromagnetic Interference (EMI) Measurements - Option 361

Keysight Technologies C Series
914 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
323
Keysight Handheld Analyzers
N99xxC User’s Guide
12 Electromagnetic Interference (EMI) Measurements –
Option 361
Requirements
EMI mode measures signals at the SA RF Input Port 2 connector.
EMI mode requires the FieldFox to have SA mode (Option 233 on
combination analyzers) installed.
Recommended, but not required:
—EMI chamber.
Preamplifier (Option 235) to improve receiver sensitivity.
—Filters
Line impedance stabilization network (LISN) – conducted emissions testing
Transient limiter – conducted emissions testing
Calibrated antenna – radiated emissions testing
Signal generator (e.g., EXG, MXG)
Set of antennas
Set of near field probes (e.g., Keysight N9311X Series of antennas and field
probes.)
EMI Option 361 measures radiated and conducted emissions. With EMI you
can measure the unintentional generation, propagation, and reception of
electromagnetic energy that might cause your device to violate
pre-compliance/compliance testing. This includes the emissions and immunity
(susceptibility) levels of electromagnetic energy.

Table of Contents