Comfort Control Unit
141
No.
Image Description Possible cause Remedy
116
Sensor for left axle
- Sensor or line defective
- Plug not inserted
- Output signal of angle encoder
outside of permissible measuring
range
- Perform a sensor test
- Check the sensor
and supply line for
damage
- Check mechanical
setting
117
Sensor for right
axle
- Sensor or line defective
- Plug not inserted
- Output signal of angle encoder
outside of permissible measuring
range
- Perform a sensor test
- Check the sensor
and supply line for
damage
- Check mechanical
setting
118
Axle valve
up/down
Broken cable or valve plug not
plugged in or overload
Check the valve and
supply line for damage
119
Axle valve left/right
Broken cable or valve plug not
plugged in or overload
Check the valve and
supply line for damage
121
Fold up blade bar
key
Button or line defective - Perform a sensor test
- Check the button or
supply line for damage
122
Unfold blade bar
key
Button or line defective - Perform a sensor test
- Check the button or
supply line for damage