Medium Control Unit
68
Pos: 19.32 /BA/I nfo-Center/La dewagen/Mediu m/Einstellung der Kratzbod engeschwindigkeit 0 % @ 28\mo d_124998163 3005_78.doc @ 272965
8.13.2 Setting of the floor conveyor speed 0 % (D/GD design only)
Turning on sensor test.
By keeping the key pressed, switch on the control unit via the key .
The control unit changes to the sensor test (pilot lamp (2) flashes).
Figure 33
Note
Since the oil capacity may vary from one tractor to another, it may be necessary to readjust the
initial speed of the floor conveyor.
Press the key (3) . (Pilot lamp (2) goes out and control lamp (4) flashes.)
Activating the tractor hydraulics.
Increase the engine speed of the tractor to nominal speed.
By pressing the key (9) or (10), decrease or increase the current of the floor
conveyor supply valve until the floor conveyor is put slightly into motion (the bar graph displays
the setting).
Press the key to switch off the control unit.