Medium Control Unit
73
Pos: 19.44 /Üb erschriften/Üb erschriften 2/P-T/S törungen - Ursac hen und Be hebung @ 2\ mod_120332582 6011_78.doc @ 65688
8.19 Malfunctions - Causes and Remedies
Pos: 19.45 /BA/I nfo-Center/La dewagen/Mediu m/Störungen_Urs ache_Beheb ung Ladewag en @ 3\mod_12 04177714249_ 78.doc @ 698 15
11 Over/under
voltage
Tractor battery defective Check battery
Tractor dynamo defective/too weak. Check dynamo
12 V power supply too weak on the tractor
side or not correctly connected with the
battery.
Connect the KRONE connection cable to
the tractor battery
13 BUS error The BUS bus was interrupted between
the control unit and the machine > loose
connection to display screen
Check the display line.
14 Incorrect
terminal
Connection to incorrect terminal. Use the correct terminal for the machine
type.
15 Incorrect
terminal
software
Terminal software and job computer not
compatible
Use correct software.
16 Control unit key
defective
Key sticks when used. Check keys.
21 Sensor error Broken cable / short circuit in a sensor. Check sensors
Pos: 19.46 /BA/-- ---Seitenum bruch------ @ 0\m od_119617531 1226_0.doc @ 4165