Medium Control Unit
67
Pos: 19.30 /BA/I nfo-Center/La dewagen/Mediu m/Einstellung der Kratzbod engeschwindigkeit 100 % @ 28\ mod_1249980 714489_78. doc @ 272940
8.13.1 Setting of the floor conveyor speed 100 % (D/GD design only)
Turning on sensor test.
By keeping the key pressed, switch on the control unit via the key .
The control unit changes to the sensor test (pilot lamp (2) flashes).
Figure. 32
Note
Since the oil capacity may vary from one tractor to another, it may be necessary to readjust the
maximum speed of the floor conveyor.
• Press the key (4) . (Pilot lamp (2) goes out and control lamp (4) flashes.)
• Activating the tractor hydraulics.
• Increase the engine speed of the tractor to nominal speed.
By pressing the key (10), increase the current of the floor conveyor supply valve
until the floor conveyor speed is no longer increasing (the bar graph displays the setting).
Press the key to switch off the control unit.
Pos: 19.31 /BA/-- ---Seitenum bruch------ @ 0\m od_119617531 1226_0.doc @ 4165