EasyManua.ls Logo

Lenze i950

Lenze i950
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.2 Second feedback system for the techology applicaon
The parameter sengs for the feedback system of the applicaon are accessed in »EASY
s
tarter« via the following path:
Sengs tab
Basic seng \ Feedback applicaon (B)
Here, you have the choice of using the following feedback systems:
R
esolver
Encoder
You can select the feedback system that you wish to use by pressing the correspondingly
named buon.
12.2.1 General
sengs
This chapter provides informaon on general feedback system sengs for the applicaon.
Parameter
Address Name / seng range / [default seng] Info
0x2C55 Load encoder/master encoder error response Via this parameter, the error response to an encoder error of applicaon
feedback B (slot B) is set.
Selecon of the response to the triggering of the encoder signal loss
monit
oring.
Only acve when used as:
Feedback system for motor control if set,
Signal source for the "posion counter" funcon.
Associated error code:
29444 | 0x7304 - RANLI_CIMES_1000_20910
0 No response
1 Fault > CiA402
2 Warning
0x2C56 Number of the absolute ascertainable revoluons of
load encoder/master encoder
Read only
Is set by the rmware according to the available version:
0: no absolute value encoder (sin/cos encoder) or resolver with num-
ber of pole pairs > 1
1: Hiperface encoder SingleTurn or resolver with number of pole
pairs = 1
> 1: Hiperface encoder Mul Turn
0x2C57 Open circuit detecon sensivity of load encoder/
master encoder
1 ... [100] ... 100 %
The sensivity can be reduced by percentage, e. g. in case of EMC inter-
ferences.
0x2E00:041 Set posion for load encoder
0 O
1 On
0x60E6:001 Addional posion encoder resoluon - encoder
increments: Load encoder/master encoder - number
of increments
Seng can only be changed if the inverter is inhibi-
ted.
Seng the number of bits to be used for resolving a mechanical revolu-
on of the secondary feedback system.
65536 16 Bit
262144 18 Bit
1048576 20 Bit
4194304 22 Bit
16777216 24 Bit
67108864 26 Bit
268435456 28 Bit
1073741824 30 Bit
0x60EB:001 Addional
posion encoder resoluon - motor revolu-
ons: Load encoder/master encoder - resoluon of
motor revoluons
1 ... [1] ... 1
Seng can only be changed if the inverter is inhibi-
ted.
Seng of the number of revoluons of the secondary feedback system.
Only seng "1" is accepted.
Conguring the feedback system
Sec
ond feedback system for the techology applicaon
General sengs
213

Table of Contents

Other manuals for Lenze i950