7.2.4 Assignment of control signals and status signals
The eldbus or system bus control words are distributed across the control signals of the listed
funcons.
Virtual mas
ter
Sync and Correcon
Controlword 00
Controlword 01
Controlword 02
Controlword 03
Controlword 04
Controlword 05
Controlword 06
Controlword 07
Field bus /System bus
0x5040:010
0x5040:011
0x5040:012
0x5040:023
0x5040:014
0x5040:015
0x5040:016
0x5040:027
0x5045:010
0x5045:011
Sync and Correction
Bit 7, Bits 25-31
Bits 0-24
Virtual Master
Fig. 33: Distribuon of the control signals
0x5045:111
0x5045:112
0x5045:113
0x5045:114
0x5045:115
Statusword 00
Statusword 01
Statusword 02
Statusword 03
Statusword 04
Statusword 05
Statusword 06
Statusword 07
Field bus /System bus
0x5040:010
0x5040:111
0x5040:112
0x5040:113
0x5040:114
0x5040:115
0x5040:116
0x5040:117
0x5045:110
Sync and Correction
Bits 3, 6, 7, 8, 25-31
Bits 0-24
Virtual Master
Fig. 34: Distribuon of the status signals