4.5 Saving the parameter sengs
During operaon with the CiA 402 device prole, no sengs are saved. The sengs are trans-
mied when the master control is started. If applicaons are used, the SD card with the
licence da
ta also serves as storage medium.
The acve applicaon is displayed in the parameter. C2013:001
The applicaon can be modied via the parameter. 40x4000
4.5.1 Save parameter sengs with »EASY Starter«
If a parameter seng has been changed with the »EASY Starter« but not yet saved in the
memory medium with mains failure protecon, the status line of the »EASY Starter« displays
the note "The parameter set was changed".
There are 3 opons to save the parameter sengs in the user memory of the storage
medium:
Click the buon in the toolbar of the »EASY Starter«
.
Pr
ess the funcon key F6.
Execute the device command "Save user data": 0x2022:003 = "On / start [1]".
Commissioning
Sa
ving the parameter sengs
Save parameter sengs with »EASY Starter«