6.2.11.3 Hardware limit switches
The
resulng setpoint velocity Virtual Master: Set velocity is used for the connuous opera-
on or cyclic operaon of the virtual master. 40x5047:001
AI1-
DI3
DI1
GO
DO1
AI1+
DI3
DI1
GI
24O
X3
Fig. 19: Front view of the plug connector X3 with analog input 1
p
v
t
v
max
(0x5020:009)
(0x2DA4:005)
(0x5021:152)
(0x500B:011)
(0x5045:011)
(0x5047:001)
(0x5042:017)
(0x5046:001)
(0x5046:002)
(0x5046:004)
(0x5046:005)
(0x5046:003)
(0x5046:030)
(0x5046:020)
Master Value Source
Source Master Values
(0x5020:014)
Source Master Values
(0x5020:014) =
Systembus
Source Master Values
(0x5020:014)
=
Systembus
Virtual Master
Master Values
Set Velocity
Virtual Master
Profile Generator
OR Error code (0x603F:000) = 0x7304 (Feedback fault slot B)
Source Master Values (0x5020:014) = Virtual Master AnalogIn 1OR
OR Status Signals Virtual Master (0x5045:110), Bit 31 (External Master Values Inactive)
System bus in Velocity
Application feedback (B)
Set Velocity Virtual Master
Analoginput 1
Reference Velocity Analoginput 1
Selected Set Velocity VM
VM Startposition
VM Zielposition
VM Dec
VM Jerk
VM Acc
VM Sync Velocity
VM Sync Slave Direction
Selected Master Velocity
Fig. 20: Analog input 1 as speed source
Connecon of the hardware limit switches
The hardware limit switches are assigned to the digital inputs via the Source for posive hard-
ware limit switch and Source for negave hardware limit switch parameters.
Limit switch source
Source for posive hardware limit switch 40x5020:004
Sour
ce for negave hardware limit switch 40x5020:005
The limit switch evaluaon responds to a posive edge.
If the limit switch connecons for the digital inputs used are to be fail-safe,
chang
e the terminal polarity of the corresponding digital inputs.
Triggering of the hardware limit switches
If either of the hardware limit switches is triggered and the signal at the input = TRUE, the
par
ametrised error response is executed. 40x500A:104
The error message "HWLimitPos" or "HWLimitNeg" is generated, irrespecve of whether the
a
xis is currently moving and in which direcon the axis is currently moving.
Acknowledge the error in order to move the axis.
Behaviour when retracng the limit switches:
If a limit switch is triggered and the error message is acknowledged, only travel requests in the
opposite direcon (retracng direcon) are possible. Travel requests in the direcon of the
limit switch are aborted in the event of an error.