16.3.6 Diagnoscs
16.3.6.1 LED status display
Notes on the connecon status to the IO-Controller can be obtained via the LEDs "BUS RDY"
and "BUS ERR" of the PR
OFINET opon (on the front of the inverter).
In addion, the LEDs "Link" and "Acvity" at the RJ45 sockets indicate the connecon status to
the network.
LED "BUS RDY" (green)
Blinking paern State Meaning
O Not connected No
connecon to the IO-Controller
Blinking
Connected IO-Controller in STOP
On
Data exchange IO-Controller in RUN (DATA_EXCHANGE)
LED "BUS ERR" (red)
Blinking paern State Meaning
O No fault No fault
ickers
IO-Device
idenes (localises) The PROFINET funcon "node ashing test" is
triggered by IO-Controller. The ickering LED
serves to idenfy (locate) an accessible IO-
Device.
Blinking
Impermissible sengs Impermissible sengs: Stack, staon name or
IP par
ameters are invalid.
On (red)
Fault Communicaon error (e. g. Ethernet cable
r
emoved)
LED "Link" (green)
Blinking paern Status/meaning
o No
connecon to the network.
on
A physical connecon to the network is
a
vailable.
LED
"Acvity" (yellow)
Blinking paern Status/meaning
o No data transfer.
on or ickers
Data is exchanged via the network.
16.3.6.2 Informaon on the network
The following parameters show informaon on the network.
Parameter
Address Name / seng range / [default seng] Info
0x2382:001 Acve PROFINET sengs: IP address
•
R
ead only
Display of the acve IP address.
0x2382:002 Acve PROFINET sengs: Subnet
•
Read only
Display of the acve subnet mask.
0x2382:003 Acve PROFINET sengs: Gateway
•
Read only
Display of the gateway address.
0x2382:004 Acve PROFINET sengs: Staon name
•
Read only
Display of the acve staon name.
0x2382:005 Acve PROFINET sengs: MAC Address
•
Read only
Display of the acve MAC address.
Conguring the network
PR
OFINET
Diagnoscs
363