7.9.1 Mark window and mark register
Set
Acvate tool mark window parameter = TRUE to acvate the funconality of the mark
window. 40x5041:129
Set
Acvate tool mark window parameter = FALSE to edit each mark. 40x5041:129
Set Mark windo
w teaching parameter = 1 to set the mark window with the teach-in funcon.
40x5041:015
In the Con
trol signals parameter, set bit 22 to acvate the mark window in the Tool mark win-
dow size parameter learned via the teach-in funcon for the following marks.
•
T
ool mark window size 40x5041:126
•
Control signals 0x5040:010 bit 22
The following table provides informaon on the status of the mark window:
Parameter name Parameter index Bit status Status
Acvate tool mark window 0x5041:129 TRUE Mark window acve
FALSE Mark window deacvated
Mark window teaching 0x5041:015 1 Mark window of the tool correcon is
learned
0 Mark window of the master value correc-
on is learned
The
gure shows the use of a mark stack. The distance from the mark sensor to the tool is
greater than the set mark distance.
Mark stack
Sensor
Virtual
sensor
UpperCorrPos
LowerCorrPos
SensorToolDistance
Fig. 61: Systemac
representaon of the mark stack with a pocket-type conveyor
Mount the mark sensor as close as possible to the axis. The further from the axis the mark
sensor is mounted, the more imprecise the cuts will be.
Up to 64 mark signals are managed in the mark stack. These marks are available to the system
at the right me to delay the mark register length. This allows the tool to be corrected to the
correct mark signal.
Conguring the "Sync and Correcon" TA
T
ool correcon
Mark window and mark register
144