7.3.3.2 Speed via analog input 1
The speed source takes the form of a percentage value from analog input 1. The Diagnoscs
of analog input 1: Scaled percent value par
ameter refers to the Reference velocity for analog
input 1 parameter.
Diagnoscs of analog input 1: Scaled percent value 40x2DA4:005
Reference velocity for analog input 1 40x5020:009
The Reference velocity for analog input 1 parameter is congured and scaled in the basic
sengs.
The resulng setpoint velocity Virtual Master: Set velocity is used for the connuous opera-
on or cyclic operaon of the virtual master. 40x5047:001
AI1-
DI3
DI1
GO
DO1
AI1+
DI3
DI1
GI
24O
X3
Fig. 42: Front view of the plug connector X3 with analog input 1
p
v
t
v
max
(0x5020:009)
(0x2DA4:005)
(0x5021:152)
(0x500B:011)
(0x5045:011)
(0x5047:001)
(0x5042:017)
(0x5046:001)
(0x5046:002)
(0x5046:004)
(0x5046:005)
(0x5046:003)
(0x5046:030)
(0x5046:020)
Master Value Source
Source Master Values
(0x5020:014)
Source Master Values
(0x5020:014) =
Systembus
Source Master Values
(0x5020:014)
=
Systembus
Virtual Master
Master Values
Set Velocity
Virtual Master
Profile Generator
OR Error code (0x603F:000) = 0x7304 (Feedback fault slot B)
Source Master Values (0x5020:014) = Virtual Master AnalogIn 1OR
OR Status Signals Virtual Master (0x5045:110), Bit 31 (External Master Values Inactive)
System bus in Velocity
Application feedback (B)
Set Velocity Virtual Master
Analoginput 1
Reference Velocity Analoginput 1
Selected Set Velocity VM
VM Startposition
VM Zielposition
VM Dec
VM Jerk
VM Acc
VM Sync Velocity
VM Sync Slave Direction
Selected Master Velocity
Fig. 43: Analog input 1 as speed source
Relevant parameters of other
funcons
Address Designaon Default seng Seng range
0x2DA4:005 Diagnoscs of analog input 1: Scaled percent value x.xx % (Read only)
0x5020:009 Reference velocity for analog input 1 500.0000 0.0000 ... 214748.3647
0x5047:001 Virtual Master: Set velocity - (Read only)
Conguring the "Sync and Correcon" TA