Address Name / seng range / [default seng] Info
0x4001 Interface selecon
Selecng the interface determines the interface that receives the signals.
0 Fieldbus network Control of the applicaon via the
eldbus.
1 Systembus network Acvaon of the applicaon via the system bus.
0x500B:011 Actual velocity
•
Read only
The current speed value is resolved with 4 decimal posions.
0x5020:009 Reference velocity for analog input 1
0.0000 ... [500.0000] ... 214748.3647
The reference speed for the percentage value of the analog input.
0x5020:014 Master value source
•
Seng can only be changed if the inverter is inhibi-
ted.
0 System bus The system bus provides the external master velocity value.
1 Load encoder The signal from the load encoder interface is taken as the master veloc-
ity value.
2 Virtual master The virtual master, whose setpoint velocity comes from the Set virtual
master velocity PDO, serves as master value master. 40x5045:011
3 Analog input 1
0x5021:152 System bus diagnoscs: Velocity (input value)
•
R
ead only
Speed conducvity
Conguring the "Sync and Correcon" TA
Mas
ter value sources
Virtual master