7.8 Master value correcon (register control)
Gener
al funcon
The master value correcon is a superimposed control loop. A master posion value is calcula-
ted based on the master velocity and with the aid of marks. This closed loop control makes it
possible to compensate for mark osets on the material, with reference to the master posi-
on. The cycle length of this corrected master posion value, which corresponds to the dis-
tance between the marks (register cycle), is specied in the Mark distance parameter.
40x5041:002
The Sensor distance parameter species the distance between the mark sensor and the posi-
on where the tool starts on the material. 40x5041:001
The Sensor distance parameter denes the posion of the sensor in the Set sensor posion
parameter within the register cycle.
Sensor dis
tance 40x5041:001
Sensor set posion 40x5042:001
Conguring the "Sync and Correcon" TA
Mas
ter value correcon (register control)