EasyManua.ls Logo

Lenze i950

Lenze i950
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
If a mark occurs in the process, the detected register posion will be compared with the sen-
sor
posion. The posions generate a dierence:
Dierence posions
Sensor se
t posion 40x5042:001
Actual mark posion 40x5042:002
The
dierence between Set sensor posion and Mark current posion is the posion error
Actual mark error. 40x5042:003
0
+
t
v
v
max
TP
φ
-
P
-
1
1
x
(0x5041:003)
(0x5042:003)
(0x5020:011)
(0x5042:001)
(0x5042:016)
(0x5041:008)
(0x5042:002)
(0x5041:005)
(0x5040:010
Bit 19)
(0x5042:006)
(0x5041:011)
(0x5042:005)
(0x5041:002)
(0x5042:017)
(0x5041:009)
(0x5041:010)
(0x5041:004)
(0x5041:012)
(0x5042:00/)
(0x5041:007)
(0x5041:006)
(0x5041:014)
(0x5042:004)
(0x5041:016)
(0x5041:017)
(0x5041:002)
DI 1
DI 2
DI 3
DI 4
Mark
window
Master Value Correction
Actual mark error
Sensor Setposition
Mark distance master
Actual gearfactor
C
orrected set
position
Activate Master value correction
Upper correction position
Mark Actposition
Max positive correction master
Selected Master
position
Gain gearfactor correction
Source TP 1
Max window marks
Correction Window reference
Lower correction position
Mark window size
Mark window offset
Max negative correction master
Corrected set
velocity
Selected Master
Velocity
Max gearfactor correction
Activate mark window master
Actual limited mark error
Enable gearfactor correction
Hold gearfactor correction
Mark distance
Correction window
Fig. 58: Master value
correcon paral signal ow
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x5020:011 TP1 source Digital input 1, posive edge [1] Selecon list
0x5041:001 Sensor distance 360.0000 0.0000 ... 214748.3647
0x5041:002 Mark distance 360.0000 0.0000 ... 214748.3647
0x5041:003 Max.
posive correcon 45.0000 0.0000 ... 214748.3647
0x5041:004 Max. negave correcon 45.0000 0.0000 ... 214748.3647
0x5041:005 Reference measuring system of correcon window Corrected master posion [1] Selecon list
0x5041:006 Upper correcon posion 350.0000 0.0000 ... 214748.3647
0x5041:007 Lower correcon posion 200.0000 0.0000 ... 214748.3647
0x5041:008 Mark window size 40.0000 0.0000 ... 214748.3647
0x5041:009 Mark window oset 0.0000 0.0000 ... 214748.3647
0x5041:010 Max. number of missed marks 20 0 ... 4294967295
Conguring the "Sync and Correcon" TA
Mas
ter value correcon (register control)
135