EasyManua.ls Logo

Lenze i950

Lenze i950
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14.3 Congure digital outputs
14.3.1
Digital output 1
Sengs for digital output 1.
Details
The digital output 1 is controlled with the trigger selected in .
The following sengs are possible for the digital output:
Inversion
Manual I/O control
0x2634:002Trigger
0
1
0
1
1 DO1
0x4016:005 0x60FE 0x2635:002 0x263C:001
X3
0x263C:002
Diagnosc parameters:
Displa
y of the logic state of the trigger signal:
Display of the logic state of the digital output: 0x4016:005
Inversion
The trigger signal of the digital output can be internally inverted logically.
Manual I/O control
The digital output can be overridden manually. Aer the funcon is acvated, the actual val-
ues are "frozen". Aerwards, each digital output can be overwrien manually.
Seng:
Acvaon: 0x263C:001
Entering the manual value: 0x263C:002
Parameter
Address Name / seng range / [default seng] Info
0x2635:002 Inversion of digital outputs: Digital output 1 Inversion of digital output 1
0 Not inverted
1 Inverted
0x4016:005 Digital output 1: Terminal state
R
ead only
Display of the logic state of output terminal X3/DO1.
0 FALSE
1 TRUE
0x263C:001 Digital outputs internal control: Acvaon
0 Aus
1 Ein
0x263C:002 Digital outputs internal control: DO1 internal control
0 Aus
1 Ein
I/O extensions and control connecons
Congure digital outputs
Digit
al output 1
311

Table of Contents

Other manuals for Lenze i950

Related product manuals