7.3.3 Virtual master
The technology applicaon allows operaon with a virtual master. In this case, a drive in the
ne
twork takes on the role of the virtual master while at the same me serving as the rst
slave drive. The generated master value is transmied to the slave drives via the system bus.
Modes of operaon
The virtual master oers the following operang modes:
Operang
mode/funcon Bit names of the "Virtual master
control signals" parameter
Parameter index Bit
Connuous operaon VM connuous 0x5045:010 Bit 25
Clocked operaon VM cycle 0x5045:010 Bit 26
Loading of starng posion Load VM posion 0x5045:010 Bit 27
Manual operaon in posive direc-
on of rotaon
Manual jog posive VM 0x5045:010 Bit 28
Manual operaon in negave
direcon of rotaon
Manual jog negave VM 0x5045:010 Bit 29
Addional
funcons for all modes of operaon
Funcon Parameter name Parameter index
Adjustment of the setpoint velocity Set velocity 0x5045:011
Bring to standsll posion Virtual master set
posion 0x5046:002
Acceleraon to setpoint velocity Virtual master acceleraon 0x5046:003
Decelerate master value Virtual master deceleraon 0x5046:004
Addional
funcons for manual operaon operang mode
Funcon Parameter name Parameter index
Accelerate Manual jog acceleraon 0x500C:182
Manual jog velocity Manual jog velocity 0x500C:181
Decelerate Manual jog deceleraon 0x500C:183
Congure jerk Manual jog jerk 0x500C:184
p
v
t
v
max
(0x5020:009)
(0x2DA4:005)
(0x5021:152)
(0x500B:011)
(0x5045:011)
(0x5047:001)
(0x5042:017)
(0x5046:001)
(0x5046:002)
(0x5046:004)
(0x5046:005)
(0x5046:003)
(0x5046:030)
(0x5046:020)
Master Value Source
Source Master Values
(0x5020:014)
Source Master Values
(0x5020:014) =
Systembus
Source Master Values
(0x5020:014)
=
Systembus
Virtual Master
Master Values
Set Velocity
Virtual Master
Profile Generator
OR Error code (0x603F:000) = 0x7304 (Feedback fault slot B)
Source Master Values (0x5020:014) = Virtual Master AnalogIn 1OR
OR Status Signals Virtual Master (0x5045:110), Bit 31 (External Master Values Inactive)
System bus in Velocity
Application feedback (B)
Set Velocity Virtual Master
Analoginput 1
Reference Velocity Analoginput 1
Selected Set Velocity VM
VM Startposition
VM Zielposition
VM Dec
VM Jerk
VM Acc
VM Sync Velocity
VM Sync Slave Direction
Selected Master Velocity
Fig. 40: Virtual master as master value source
Parameter
Address Name / seng range / [default seng] Info
0x2DA4:005 Diagnoscs of analog input 1: Scaled percent value
R
ead only: x.xx %
Current value of the analog input is resolved with 2 decimal places.
Display of the actual value at the analog input, scaled with the following
parameters:
Minimum value for scaling. 40x2636:013
Maximum value for scaling. 40x2636:014
Conguring the "Sync and Correcon" TA
Mas
ter value sources
Virtual master
104