M
Slave
Dj
TP
+
Systembus
Dj
TP
+ +
Offset
Trimming
Dj
è
ç
Manual jog
n
t
n
t
HALT
Halt
n
t
QSP Application
STOP
Fig. 30: Signal ow in the technology applicaon
In the "Technology applicaon" dialogue of the »EASY Starter« soware, the parameter Appli-
caon
selecon shows which technology applicaon is acve. The technology applicaon can
be modied in this dialogue. 40x4000
Parameter
Address Name / seng range / [default seng] Info
0x4000 Applicaon
selecon
Seng can only be changed if the inverter is inhibi-
ted.
0 "CiA 402" technology applicaon
10 "Speed Control" technology applicaon
20 "Table Posioning" technology applicaon
40 "Electronic Gearbox" technology applicaon
41 "Sync and Correcon" technology applica-
on
50 "Winder Dancer" technology applicaon
51 "Winder Tension" technology applicaon
10000 "User" technology applicaon
7.1 Control sengs
General variables such as starng values, reference variables, and signal sources must be
dened before the control system of the technology applicaon is congured.
Sengs in "EASY Starter":
Sengs tab
T
echnology applicaon parameter dialogue for
Applicaon
selecon 40x4000
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x4001 Interface
selecon Fieldbus network [0] Selecon list
0x5020:007 Applicaon quick stop source FALSE [0] Selecon list
0x5020:008 Source of fault reset FALSE [0] Selecon list
0x5020:014 Master value source System bus [0] Selecon list
0x5020:030 Source of digital output 1 Ready to switch on [0] Selecon list
0x5040:006 Display value 1 [8] Selecon list
Conguring the "Sync and Correcon" TA
Con
trol sengs
90