6.4.2.2 Source of touch probe me stamp
The T
ouch probe system bus source parameter serves to set the source of the touch probe
me stamp. 40x5020:011
Time stamp TP (0x5021:165)
System bus outputs
Source TP 1
(0x5020:011)
Time stamp TP: System bus in
(0x5021:155)
DigIn1 - Positive edge
DigIn4 - Negative edge
DigIn4 - Any edge
Fig. 25:
Selecon of the source of the touch probe me stamp
Parameter
Address Name / seng range / [default seng] Info
0x5020:011 TP1 source The sensor source and the edge to be evaluated are selected via the
par
ameter (rising, falling, any)
0 External source Source: System bus
1 Digital input 1, posive edge
2 Digital input 1, negave edge
3 Digital input 1, any edge
11 Digital input 2, posive edge
12 Digital input 2, negave edge
13 Digital input 2, any edge
21 Digital input 3, posive edge
22 Digital input 3, negave edge
23 Digital input 3, any edge
31 Digital input 4, posive edge
32 Digital input 4, negave edge
33 Digital input 4, any edge
0x5020:012 TP2 source
0 External source
1 Digital input 1, posive edge
2 Digital input 1, negave edge
3 Digital input 1, any edge
11 Digital input 2, posive edge
12 Digital input 2, negave edge
13 Digital input 2, any edge
21 Digital input 3, posive edge
22 Digital input 3, negave edge
23 Digital input 3, any edge
31 Digital input 4, posive edge
32 Digital input 4, negave edge
33 Digital input 4, any edge
0x5021:155 System bus diagnoscs: Time stamp (input value)
R
ead only: x ns
Time stamp of the master axis
0x5021:165 System bus diagnoscs: Time stamp (output value)
Read only: x ns
Time stamp of the touchprobe source in ns selected via source TP1
0x5020:011.
Technology applicaon (TA) basic sengs
System bus
communicaon
Outputs
84