7.8.1 Mark window and mark register
+
+
1
2
3
4
5
6
1
3
2
4
5
6
Sensor distance master
0x5041:001
Offset mark window
0x5041:009
Mark distance master
0x5041:002
Mark window size
0x5041:008
Lower correction position
0x5041:007
Upper correction position
0x5041:006
Fig. 59: Schemac pass of the print marks
A mark window can be
acvated so the mark sensor is not triggered unintendedly. If the
parameter Acvate mark window = TRUE, the window funcon is acve. 0x5041:014
Parameter
Address Name /
seng range / [default seng] Info
0x5041:014 Acvate mark window for master value
Bit 0 FALSE Mark window deacvated
Bit 1 TRUE Mark window acvated
For the master value
correcon to work, the mark window must be learned. This can happen
in the engaged and disengaged state:
State
Engaged Master value and drive axis move
Disengaged Master value moves and drive axis is immobile
Learn mark window in disengaged status
If the mark window is learned in the disengaged state, the corrected master value posion is
wrien to the Sensor set posion parameter when the rst mark is detected. 40x5042:001
At the same me, the mark window from the Mark window size parameter is placed symmet-
rically around the detected mark. 40x5041:008
Learn mark window in engaged status
If the mark window is learned in the engaged state, the mark window is acvated when the
rst mark is detected. The register posion is not set.
The mark window can be shied to the Mark windo
w oset parameter. 40x5041:009
Conguring the "Sync and Correcon" TA
Master value correcon (register control)
Mark window and mark register
137