7.8.1 Mark window and mark register
+
+
1
2
3
4
5
6
1
3
2
4
5
6
Sensor distance master
0x5041:001
Offset mark window
0x5041:009
Mark distance master
0x5041:002
Mark window size
0x5041:008
Lower correction position
0x5041:007
Upper correction position
0x5041:006
Fig. 59: Schemac pass of the print marks
A mark window can be
acvated so the mark sensor is not triggered unintendedly. If the
parameter Acvate mark window = TRUE, the window funcon is acve. 0x5041:014
Parameter
Address Name /
seng range / [default seng] Info
0x5041:014 Acvate mark window for master value
Bit 0 FALSE Mark window deacvated
Bit 1 TRUE Mark window acvated
For the master value
correcon to work, the mark window must be learned. This can happen
in the engaged and disengaged state:
State
Engaged Master value and drive axis move
Disengaged Master value moves and drive axis is immobile
Learn mark window in disengaged status
If the mark window is learned in the disengaged state, the corrected master value posion is
wrien to the Sensor set posion parameter when the rst mark is detected. 40x5042:001
At the same me, the mark window from the Mark window size parameter is placed symmet-
rically around the detected mark. 40x5041:008
Learn mark window in engaged status
If the mark window is learned in the engaged state, the mark window is acvated when the
rst mark is detected. The register posion is not set.
The mark window can be shied to the Mark windo
w oset parameter. 40x5041:009
Conguring the "Sync and Correcon" TA
Master value correcon (register control)
Mark window and mark register