6.3.3 Source of digital output 1
The signal for digital output 1 is selected via the Sour
ce for digital output 1 parameter.
40x5020:030
0x5020:030
(Source digital output 1)
Ready to switch on
Drive fault
Homing done
Positioning profile done
Brake release out
Signal from fieldbus
Dig out 1
Fig. 22: Selecon of "Digital output 1"
Parameter
Address Name / seng range / [default seng] Info
0x5020:030 Source of digital output 1 Signal selecon for the digital output 1.
0 Ready to switch on
1 Fault
2 Homing done
3 Prole done
4 Brake opened
5 Network signal
6.3.4 Source of monitoring signal
A monitoring signal can be selected for control word 6 and another one for control word 7.
The source for the monitoring signal to be output is selected via the Sour
ce for monitoring
signal parameter. The number of decimal posions transmied depends on the value selec-
ted.
Selecon for control word 6:
Selecon for control word 7:
The source for the monitoring signal to be output is selected via the Source for monitoring
signal parameter. The number of decimal posions transferred depends on the value selected.
0x5030:006
Technology applicaon (TA) basic sengs
Dening control sources
Source of monitoring signal
81