16.1.6.3 Ready to switch on
This is the device state of the inverter aer the device has been inialised successfully and
aer the command has been triggered.
A change to this device state also takes place if the "" command was triggered in the states
"S
witched on" or ".
Pr
ocess data monitoring is acve.
Communicaon is possible.
The DC-bus v
oltage is available.
The inverter can be parameterised.
If the internal holding brake control (0x2820:001) is acve in the inverter, the motor brake
is closed.
Operaon is inhibited.
1 From all states
2 Power secon inhibited (pulse inhibit)
3 Power secon enabled
Bit paern in the CiA 402 status word (0x6041)
Bit 15 ... 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Reserved
(specic)
Warning
acve
Operaon
inhibited
Quick stop
acve
DC bus ready
f
or operaon
Fault acve Operaon
enabled
Switched on Ready to
switch on
X X 0 1 X 0 0 0 1
X = state is not relevant