The distance between the touch probe sensor and the posion where the tool starts is
assigned via the T
ool sensor distance parameter. 40x5041:121
The "mark stack" funcon is automacally acvated when the Tool sensor distance parameter
is greater than der Cycle length parameter.
Parameter
Tool sensor distance 40x5041:121
Cycle length 40x500A:031
Aer a mark has been detected, the value of the mark deviaon is released for correcon only
if the posion in the register cycle has covered the distance of the mark register.
Parameter
Address Name / seng range / [default seng] Info
0x500A:031 Cycle length
0.0001 ... [360.0000] ... 214748.3647
Seng can only be changed if the inverter is inhibi-
t
ed.
The cycle length for an unlimited traversing range denes the posion
where the measuring system is repeated (posion return to 0).
0x5041:015 Mark window teaching
0 Master value correcon
1 Tool correcon
0x5041:120 Acvate tool correcon
false FALSE
true TRUE
0x5041:121 Tool sensor distance
0.0000 ... [360.0000] ... 214748.3647
0x5041:126 Tool mark window size
0.0000 ... [40.0000] ... 214748.3647
0x5041:127 Tool mark window oset
0.0000 ... [0.0000] ... 214748.3647
0x5041:129 Acvate tool mark window
false Deacvated
true Acvated
0x5042:140 Tool sensor set posion
R
ead only
7.9.2 Mark failure detecon
If the output is set via bit 23 in the St
atus signals parameter, no mark was detected within the
congured mark window. 40x5040:110 Bit
23
In this case, an ideal virtual mark for the system is created. Subsequent funcons can connue
to be executed.
The maximum number of mark failures is set via the Max. number of missed marks (tool)
parameter. If no mark is detected within the mark window, an internal counter is incremented.
If the number of failed marks reaches the limit set in the Max. number of missed marks (tool)
parameter, a corresponding error is output at the error output of the technology applicaon.
40x5041:128
Parameter
Address Name / seng range / [default seng] Info
0x5041:128 Max. number of missed marks (tool)
0 ... [20] ... 4294967295
Conguring the "Sync and Correcon" TA
T
ool correcon
Mark failure detecon
145