7.9.3 Posion
correcon
The correcon window species the posion range. The tool posion is corrected within the
posion range. The posion of the correcon window is specied via the parameters Tool
lower correcon posion and Tool upper correcon posion.
T
ool lower correcon
posion 40x5041:125
Tool upper correcon posion 40x5041:124
The parameters are set in the unit of the tool axis.
The Tool sensor distance parameter species the distance between the touch probe sensor
and the zero posion of the tool on the material. 40x5041:121
Sensor
Slave
LowerCorrPosUpperCorrPos
Correction range
Reference position
Fig. 62: Homing on the y without mark stack
Parameter
Address Name / seng range / [default seng] Info
0x5041:121 Tool sensor distance
0.0000 ... [360.0000] ... 214748.3647
0x5041:122 Max. posive tool correcon
0.0000 ... [45.0000] ... 214748.3647
0x5041:123 Max. negave tool correcon
0.0000 ... [45.0000] ... 214748.3647
0x5041:124 Tool upper correcon
posion
0.0000 ... [350.0000] ... 214748.3647
0x5041:125 Tool lower correcon posion
0.0000 ... [180.0000] ... 214748.3647
0x5041:130 Acvate tool correcon
false Deacvated
true Acvated
0x5042:141 Actual posion tool correcon mark
Read only
0x5042:142 Actual tool error
Read only
Conguring the "Sync and Correcon" TA
T
ool correcon
Posion correcon
146