7.9.3 Posion
correcon
The correcon window species the posion range. The tool posion is corrected within the
posion range. The posion of the correcon window is specied via the parameters Tool
lower correcon posion and Tool upper correcon posion.
•
T
ool lower correcon
posion 40x5041:125
•
Tool upper correcon posion 40x5041:124
The parameters are set in the unit of the tool axis.
The Tool sensor distance parameter species the distance between the touch probe sensor
and the zero posion of the tool on the material. 40x5041:121
Sensor
Slave
LowerCorrPosUpperCorrPos
Correction range
Reference position
Fig. 62: Homing on the y without mark stack
Parameter
Address Name / seng range / [default seng] Info
0x5041:121 Tool sensor distance
0.0000 ... [360.0000] ... 214748.3647
0x5041:122 Max. posive tool correcon
0.0000 ... [45.0000] ... 214748.3647
0x5041:123 Max. negave tool correcon
0.0000 ... [45.0000] ... 214748.3647
0x5041:124 Tool upper correcon
posion
0.0000 ... [350.0000] ... 214748.3647
0x5041:125 Tool lower correcon posion
0.0000 ... [180.0000] ... 214748.3647
0x5041:130 Acvate tool correcon
false Deacvated
true Acvated
0x5042:141 Actual posion tool correcon mark
•
Read only
0x5042:142 Actual tool error
•
Read only
Conguring the "Sync and Correcon" TA
T
ool correcon
Posion correcon
146