EasyManua.ls Logo

Lenze i950

Lenze i950
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Start, stop and rotang
direcon commands
8.1 Control selecon
Parameter
Address Name / seng range / [default seng] Info
0x2824 Control selecon
Seng can only be changed if the inverter is inhibi-
t
ed.
Selecon of the type of inverter control.
0 Flexible I/O conguraon This selecon enables a exible assignment of the start, stop, and rotat-
ing direcon commands with digital signal sources.
Digital signal sources can be digital inputs, network and keypad.
The I/O conguraon is made via the parameters 0x2631:xx (P400.xx).
1 Keypad This selecon enables the motor to be started exclusively via the start
k
ey of the keypad. Other signal sources for starng the motor are
ignored.
Start motor Stop motor
Not
e!
The funcons "Enable inverter" and "Run" must be set to TRUE to
start the motor.
If jog operaon is acve, the motor cannot be stopped via the
keypad key.
Start, stop and rotang
direcon commands
Control selecon