17.4 Enabling the device
P
arameter
Address Name / seng range / [default seng] Info
0x2822:001 Axis commands: Enable inverter Parameters for interacon with engineering tools.
0 Inverter inhibited
1 Inverter enabled
17.5 Restart device
If the inverter communicates with the master as network node via EtherCAT:
execung the device command may cause an interrupon of the EtherCAT com-
municaon with the master and a standsll of the drive.
Parameter
Address Name / seng range / [default seng] Info
0x2022:035 Device commands: Restart Device Restart of the device.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
17.6 Restarng Extended Safety
P
arameter
Address Name / seng range / [default seng] Info
0x2022:041 Device commands: Restart extended safety
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)
17.7 Export logbook
The export of the complete logbook can be started with the 0x2022:036 parameter.
Parameter
Address Name / seng range / [default seng] Info
0x2022:036 Device commands: Export Logbook Exports the logbook for the upload into the engineering tools.
0 O / ready Only status feedback
1 On / start Execute device command
2 In progress Only status feedback
3 Acon cancelled
4 No access
5 No access (Inverter disabled)