EasyManua.ls Logo

Lenze i950

Lenze i950
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
Address Name / seng range / [default seng] Info
0x5040:023 External posion
oset
-214748.3648 ... [0.0000] ... 214748.3647
0x5041:022 Oset direcon allowed
0 Both direcons
1 Master value direcon
0x5041:024 Trimming - posion dierence
0.0000 ... [1.0000] ... 214748.3647
0x5041:025 Trimming - velocity
-214748.3648 ... [50.0000] ... 214748.3647
0x5041:026 Trimming - acceleraon
-21474836.48 ... [100.00] ... 21474836.47
0x5041:027 Trimming - deceleraon
-21474836.48 ... [100.00] ... 21474836.47
0x5041:028 Jerk oset
-21474836.48 ... [10000.00] ... 21474836.47
0x5041:053 Internal posion oset
-214748.3648 ... [0.0000] ... 214748.3647
0x5041:058 Load oset
false
true
0x5042:021 Set velocity aer measuring system alignment
Read only
0x5042:025 Acve posion oset
R
ead only
0x5042:026 Velocity oset
Read only
0x5042:027 Trimming posion
oset
R
ead only
0x5042:028 Trimming - velocity oset
R
ead only
0x5042:029 Total posion
oset
R
ead only
0x5042:030 Total velocity oset
Read only
7.5 Posion
oset from master
Relevant parameters of other funcons
Address Designaon Default seng Seng range
0x5040:023 External posion
oset 0.0000 -214748.3648 ... 214748.3647
0x5041:022 Oset direcon allowed Master value direcon [1] Selecon list
0x5041:025 Trimming - velocity 50.0000 -214748.3648 ... 214748.3647
0x5041:026 Trimming - acceleraon 100.00 -21474836.48 ... 21474836.47
0x5041:027 Trimming - deceleraon 100.00 -21474836.48 ... 21474836.47
0x5041:028 Jerk oset 10000.00 -21474836.48 ... 21474836.47
0x5041:053 Internal posion oset 0.0000 -214748.3648 ... 214748.3647
0x5041:058 Load oset 0
Conguring the "Sync and Correcon" TA
Posion
oset from master