16.4.3 Process data transfer
In the system bus network …
the se
tpoint process data (master to slave) are set via the system bus master inside the
technology applicaon;
the actual process data (slave to master) is set via the slave device.
Data mapping
All inverter i950 slave devices have a xed generic data mapping. This data mapping enables
the use of the sla
ve devices with an i950 inverter as system bus master and with other Ether-
CAT-based master control systems (PLC).
The pr
ocess data is set to 8 double words (32 bytes) for each direcon.
Output data direcon: From Master to Slave.
Output da
ta: 0xA200:001 ... 0xA200:008
Input data direcon: From Slave to Master.
Input data: 0xA680:001 ... 0xA680:008
This xed data mapping is automacally acvated as master for an i950 inverter.
The process data is transmied cyclically in a 1 ms cycle between the master and the
slaves.
The process data transfer is synchronised by the "Distributed Clocks" EtherCAT mechanism.
A i950 master device provides the DC master via the internal slave.
The data in the slaves is accepted synchronously with the PLC program in the master.
All slaves are synchronised with a reference clock, the so-called "DC master".
Parameter
Address Name / seng range / [default seng] Info
0xA200:001 Systembus output data: Systembus data output 1
R
ead only
Generic system bus output data from the PLC to the inverter.
0xA200:002 Systembus output data: Systembus data output 2
Read only
0xA200:003 Systembus output data: Systembus data output 3
Read only
0xA200:004 Systembus output data: Systembus data output 4
Read only
0xA200:005 Systembus output data: Systembus data output 5
Read only
0xA200:006 Systembus output data: Systembus data output 6
Read only
0xA200:007 Systembus output data: Systembus data output 7
Read only
0xA200:008 Systembus output data: Systembus data output 8
Read only
0xA680:001 Systembus input data: Systembus data input 1
0 ... [0] ... 4294967295
Generic system bus input data from the inverter to the PLC.
0xA680:002 Systembus input data: Systembus data input 2
0 ... [0] ... 4294967295
0xA680:003 Systembus input data: Systembus data input 3
0 ... [0] ... 4294967295
0xA680:004 Systembus input data: Systembus data input 4
0 ... [0] ... 4294967295
0xA680:005 Systembus input data: Systembus data input 5
0 ... [0] ... 4294967295
0xA680:006 Systembus input data: Systembus data input 6
0 ... [0] ... 4294967295
0xA680:007 Systembus input data: Systembus data input 7
0 ... [0] ... 4294967295
0xA680:008 Systembus input data: Systembus data input 8
0 ... [0] ... 4294967295
Conguring the network
E
therCAT system bus
Process data transfer
370