Fig. 6: Posion
representaon
1
Cycle length 40x500A:031
2 Posion in the machine measuring
s
ystem
3 Posion in the motor measuring sys-
t
em
The kinemac parameters for the second encoder serve to dene the conversion of an impor-
ted encoder posion or encoder speed in machine units.
Parameter
Address Name / seng range / [default seng] Info
0x500A:030 Travel range
•
Seng can only be changed if the inverter is inhibi-
t
ed.
Selecon of the traversing range for the motor
0 Modulo Unlimited traversing range (turntable). The cycle length must also be
specied here.
1 Limited Linearly limited traversing range (spindle drive).
0x500A:031 Cycle length
0.0001 ... [360.0000] ... 214748.3647
•
Seng can only be changed if the inverter is inhibi-
ted.
The cycle length for an unlimited traversing range denes the posion
where the measuring system is repeated (posion return to 0).
0x500B:030 Travel range
•
Seng can only be changed if the inverter is inhibi-
ted.
Selecon of the traversing range with regard to the encoder posion.
0 Modulo Unlimited traversing range (turntable). The cycle length must also be
specied here.
1 Limited Linearly limited traversing range (spindle drive).
0x500B:031 Cycle length
0.0001 ... [360.0000] ... 214748.3647
•
Seng can only be changed if the inverter is inhibi-
t
ed.
The cycle length for an unlimited traversing range denes the posion
where the measuring system is repeated (posion return to 0).
Technology applicaon (TA) basic sengs
Kinemac sengs
Motor/encoder travel ranges and cycle length