Address Name / seng range / [default seng] Info
0x2C5A:007 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Start-
bit Da
tenpaket 3
0 ... [0] ... 30
Seng can only be changed if the inverter is inhibi-
ted.
Indicates the posion in the telegram where data packet 3 begins.
0x2C5A:008 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Länge
Posionsdaten
0 ... [25] ... 30
Seng can only be changed if the inverter is inhibi-
ted.
SSI posion data length
0x2C5A:009 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Länge
Da
tenpaket 1
0 ... [0] ... 30
Seng can only be changed if the inverter is inhibi-
ted.
Length of data packet 1.
0x2C5A:010 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Länge
Da
tenpaket 2
0 ... [0] ... 30
Seng can only be changed if the inverter is inhibi-
ted.
Length of data packet 2.
0x2C5A:011 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Länge
Datenpaket 3
0 ... [0] ... 30
Seng can only be changed if the inverter is inhibi-
ted.
Length of data packet 3.
0x2C5A:012 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Codier-
ung Posionsdaten
Seng can only be changed if the inverter is inhibi-
t
ed.
Coding of posion data word (read only).
If a value of "0" is set for the posion data length in 0x2C4A:008, then
the value displayed for this parameter is also "0".
0 Binär
1 Gray
0x2C5A:013 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Codier-
ung Datenpaket 1
Seng can only be changed if the inverter is inhibi-
ted.
Coding of data packet 1
0 Binär
1 Gray
0x2C5A:014 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Codier-
ung Datenpaket 2
Seng can only be changed if the inverter is inhibi-
ted.
Coding of data packet 2
0 Binär
1 Gray
0x2C5A:015 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Codier-
ung Da
tenpaket 3
Seng can only be changed if the inverter is inhibi-
ted.
Coding of data packet 3
0 Binär
1 Gray
0x2C5A:016 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Roh-
daten Posion
R
ead only
Raw value of
posion data word (read only).
If a value of "0" is set for the posion data length in 0x2C4A:008 , then
the value displayed for this parameter is also "0".
0x2C5A:017 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Roh-
daten Datenpaket 1
Read only
Raw value of data packet 1 (read only).
If a value of "0" is set for the data packet length 1 in 0x2C4A:013 , then
the value displayed for this parameter is also "0".
0x2C5A:018 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Roh-
daten Datenpaket 2
Read only
Raw value of data packet 2 (read only).
If a value of "0" is set for the data packet length 2 in 0x2C4A:014 , then
the value displayed for this parameter is also "0".
0x2C5A:019 Protokoll-Parameter Lastgeber/Leitgeber (SSI): Roh-
daten Datenpaket 3
Read only
Raw value of data packet 3 (read only).
If a value of "0" is set for the data packet length 3 in 0x2C4A:015 , then
the value displayed for this parameter is also "0".
Conguring the feedback system
Sec
ond feedback system for the techology applicaon
Encoder sengs
221