Gocator Line Profile Sensors: User Manual
Gocator Device Files • 489
Element Type Description
SpotWidthMax.value 32s Value in use by the sensor, useful for determining value when
used is false.
SpotWidthMax.min 32s Minimum allowed spot detection maximum value.
SpotWidthMax.max 32s Maximum allowed spot detection maximum value.
SpotSelectionType 32s
Spot selection type
0 – Best. Picks the strongest spot in a given column.
1 – Top. Picks the spot which is most Top/Left on the imager
2 – Bottom. Picks the spot which is most Bottom/Right on the
imager
3 – None. All spots are available. This option may not be available
in some configurations.
4 – Continuity. Picks the most continuous spot.
SpotSelectionType.used Bool Determines if the setting’s value is currently used.
SpotSelectionType.value 32s Value in use by the sensor, useful for determining value when
used is false.
SpotSelectionType.options 32s
(CSV)
List of available spot selection types.
CameraGainAnalog 64f Analog camera gain factor.
CameraGainAnalog.used Bool Determines if the setting’s value is currently used.
CameraGainAnalog.value 64f Value in use by the sensor, useful for determining value when
used is false.
CameraGainAnalog.min 64f Minimum value.
CameraGainAnalog.max 64f Maximum value.
CameraGainDigital 64f Digital camera gain factor.
CameraGainDigital.used Bool Determines if the setting’s value is currently used.
CameraGainDigital.value 64f Value in use by the sensor, useful for determining value when
used is false.
CameraGainDigital.min 64f Minimum value.
CameraGainDigital.max 64f Maximum value.
DynamicSensitivity 64f Dynamic exposure control sensitivity factor. This can be used to
scale the control setpoint.
DynamicSensitivity.used Bool Determines if the setting’s value is currently used.
DynamicSensitivity.value 64f Value in use by the sensor, useful for determining value when
used is false.
DynamicSensitivity.min 64f Minimum value.
DynamicSensitivity.max 64f Maximum value.
DynamicThreshold 32s Dynamic exposure control threshold. If the detected number of
spots is fewer than this number, the exposure will be increased.