EasyManuals Logo

LMI Technologies Gocator 2500 Series User Manual

Default Icon
800 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #579 background imageLoading...
Page #579 background image
Gocator Line Profile Sensors: User Manual
Protocols • 579
Field Type Offset Description
deviceId 32u 0 Serial number of the device.
address[4] byte 4 IP address (most significant byte first).
modelName[32] char 8 Model name.
firmwareVersion[4] byte 40 Firmware version (most significant byte first).
state 32s 44
Sensor state
-1 – Conflict
0 – Ready
1 – Running
For more information on states, see Control Commands on page
575.
role 32s 48
Sensor role
0 – Main
1 – Buddy
mainId 32u 52 Serial number of the main device, or zero.
buddyableStatus 32s 56
Whether or not the device can be buddied:
1 – Can be buddied
Errors:
0 – Unbuddiable (General Error)
-100 – Already buddied
-99 – Invalid State (e.g. running)
-98 – Version Mismatch
-97 – Model Mismatch
Remote Info
Field Type Offset Description
deviceId 32u 2 Serial number of the device.
state k32s 6
Buddy state
2 - Connecting
1 – Connected
Errors:
0 – Unbuddiable (General Error)
-100 – Already buddied
-99 – Invalid State (e.g. running)
-98 – Version Mismatch
-97 – Model Mismatch
-95 – Device Missing
Buddy Info

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2500 Series and is the answer not in the manual?

LMI Technologies Gocator 2500 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2500 Series
CategoryAccessories
LanguageEnglish

Related product manuals