Table of Functions
324
Code
Comm.
Address
Name
LCD
Display
Setting Range
Initial
Value
Property*
V/F
SL
Ref.
8
FieldBus
9
UserSeqLi
nk
12
Pulse
54
34
0h1436
Positive-
direction
reverse
torque limit
FWD
+Trq Lmt
0.0-200.0(%)
180
O/A
X
I/P
p.190
55
34
0h1437
Positive-
direction
regeneration
torque limit
FWD
Trq Lmt
0.0-200.0(%)
180
O/A
X
I/P
p.190
56
34
0h1438
Negative-
direction
regeneration
torque limit
REV +Trq
Lmt
0.0-200.0(%)
180
O/A
X
I/P
p.190
57
34
0h1439
Negative-
direction
reverse
torque limit
REV Trq
Lmt
0.0-200.0(%)
180
O/A
X
I/P
p.190
62
34
0h143E
Speed limit
Setting
Speed Lmt
Src
0
Keypad-1
0:
Keypa
d-1
X/A
X
I/P
-
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
7
FieldBus
8
UserSeqLi
nk
63
34
0h143F
Positive-
direction
speed limit
FWD
Speed Lmt
0.00~ Maximum
frequency (Hz)
60.00
O/A
X
I/P
-
64
34
0h1440
Negative-
direction
speed limit
REV
Speed Lmt
0.00~ Maximum
frequency (Hz)
60.00
O/A
X
I/P
-
65
34
0h1441
Speed limit
operation gain
Speed Lmt
Gain
100~5000[%]
500
O/A
X
I/P
-
69
35
PM speed
search current
SS Pulse
Curr
15
10~10
0
O/A
X
P
34
Displayed when dr.09 is set to 4 (IM Sensorless). This will change the initial value of the
parameter at Ad.74 (Torque limit) to 150%.