41
Installing the Inverter
30-75kW
Input Terminal Labels and Descriptions
Function
Label
Name
Description
Multi-
function
terminal
configuration
P1P7
Multi-function
Input 1-7
Configurable for multi-function input terminals.
(Standard I/O is only provided for P5.)
CM
Common
Sequence
Common terminal for analog terminal inputs and
outputs.
Analog input
configuration
VR
Potentiometer
frequency
reference input
Used to setup or modify a frequency reference via
analog voltage or current input.
Maximum Voltage Output: 12V
Maximum Current Output: 100mA,
Potentiometer: 15
V1
Voltage input for
frequency
reference input
Used to setup or modify a frequency reference via
analog voltage input terminal.
Unipolar: 010V (12V Max.)
Bipolar: -1010V (±12V Max.)
I2
Voltage/current
input for
Used to setup or modify a frequency reference via
analog voltage or current input terminals.

Table of Contents