Installing the Inverter
44
Function
Label
Name
Description
A1/C1/B1
Fault signal
output
Sends out alarm signals when the inverter’s
safety features are activated (AC 250V <1A, DC
30V < 1A).
Fault condition: A1 and C1 contacts are
connected (B1 and C1 open connection)
Normal operation: B1 and C1 contacts are
connected (A1 and C1 open connection)
A2, C2
Multi-functional
relay output
terminal
The signal is generated while operating. Define
and use the multi-functional relay output terminal
(Less than AC250 V 5A, Less than DC30 V 5A).
Communication
S+/S-/SG
RS-485 signal
line
Used to send or receive RS-485 signals. Refer to
7 RS-485 Communication Features on page 273
for more details.
NC
NC
Not in use.
Preinsulated Crimp Terminal Connectors (Bootlace Ferrule) .
Use preinsulated crimp terminal connectors to increase reliability of the control terminal
wiring. Refer to the specifications below to determine the crimp terminals to fit various cable
sizes.
P/N
Cable Spec.
Dimensions (inches/mm)
Manufacturer
AWG
mm
2
L*
P
d1
D
CE002506
26
0.25
10.4
6.0
1.1
2.5
JEONO
(Jeono Electric,
http://www.jeono.com/)
CE002508
12.4
8.0
CE005006
22
0.50
12.0
6.0
1.3
3.2
CE007506
20
0.75
12.0
6.0
1.5
3.4
* If the length (L) of the crimp terminals exceeds 0.5 (12.7mm) after wiring, the control
terminal cover may not close fully.