EasyManua.ls Logo

Mazda 2002 6 - Page 1200

Mazda 2002 6
1248 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONTROL SYSTEM
U49
U
1O Water
temperature
sensor input
Water temperature
sensor
Depends on temperature
surrounding sensor
See Figure
4
Inspect for continuity
(Climate control unitwater
temperature sensor: 1OA,
1IB)
Inspect for short circuit
(Climate control unitwater
temperature sensor: 1OA)
Inspect water temperature
sensor
Inspect terminal voltage of
climate control unit (2H, 2L)
1P A/C Refrigerant
pressure switch
Fan switch at OFF
12
Inspect for continuity or
short circuit (Climate control
unitrefrigerant pressure
switch: 1PA (Dual-
pressure type), 1PC
(Triple-pressure type))
(Refrigerant pressure
switchPCM: B1AC)
Inspect refrigerant pressure
switch
Inspect PCM terminal
voltage (1AC)
(See F45 PCM
INSPECTION )
Fan switch at 1st
position, A/C switch ON
Below 1.0
Inspect terminal voltage of
climate control unit (2H, 2L)
1Q Evaporator
temperature
sensor input
signal
Evaporator
temperature sensor
Depends on temperature
surrounding sensor
See Figure
1
Inspect for continuity
(Climate control unit
evaporator temperature
sensor: 1QA, 1IB)
Inspect for short circuit
(Climate control unit
evaporator temperature
sensor: 1QA)
Inspect evaporator
temperature sensor
Inspect terminal voltage of
climate control unit (2H, 2L)
1R ——
1S Solar radiation
sensor input
Solar radiation
sensor
Incandescent light (60W)
shining on solar
radiation sensor from
distance of approx.
100mm {3.9 in}
4.0
Inspect for continuity or
short circuit (Climate control
unitsolar radiation sensor:
1SB, 1BA)
Inspect terminal voltage of
climate control unit (1B)
Inspect solar radiation
sensor
Light to solar radiation
sensor block
Below 1.0
1T GND Ground Under any condition
Below 1.0
Inspect for continuity
(Climate control unit
ground: 1TGND)
Inspect center panel
1U Potentiometer
signal
Air mix actuator Set temperature at MAX
COLD
0.6
Inspect for continuity or
short circuit (Climate control
unitair mix actuator: 1U
C)
Inspect air mix actuator
Inspect terminal voltage of
climate control unit (1B)
Set temperature at MAX
HOT
4.3
1V ——
Terminal Signal Connected to Test condition Voltage (V) Action

Table of Contents

Other manuals for Mazda 2002 6

Related product manuals