1096
8 BUILT-IN ETHERNET FUNCTION INSTRUCTIONS
8.2 Socket Communications Instructions
Sending data
SP.SOCSND
This instruction sends the data to the external device of the specified connection.
Execution condition
Setting data
Description, range, data type
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
Applicable devices
Ladder ST
ENO:=SP_SOCSND(EN,U,s1,s2,s3,d);
FBD/LD
Instruction Execution condition
SP.SOCSND
Operand Description Range Data type Data type (label)
(U) Dummy String ANYSTRING_SINGLE
(s1) Connection number 1 to 16 16-bit signed binary ANY16
(s2) Start device where control data is stored Refer to the control data. Word ANY16_ARRAY
(Number of elements: 2)
(s3) Start device for storing the send data Word ANY16
*1
(d) Device that turns on for one scan upon completion of the
instruction
When the instruction completes with an error, (d)+1 also
turns on.
Bit ANYBIT_ARRAY
(Number of elements: 2)
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
Operand Bit Word Double word Indirect
specification
Constant Others
(U)
X, Y, M, L,
SM, F, B,
SB, FX, FY
J\ T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K, H E $
(U) 
(s1) 
(s2) 
(s3) 
(d) 
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(U) (s1) (s2) (s3) (d)
EN ENO
U
s1
d
s2
s3