894
7 APPLICATION INSTRUCTIONS
7.17 Pulse Related Instructions
7.17 Pulse Related Instructions
Measuring the density of pulses
SPD
This instruction counts the device input only for the specified time.
Execution condition
Setting data
Descriptions, ranges, and data types
*1 Only labels assigned to device (X) can be used.
Applicable devices
*1 Only X can be used. Note, however, that it can be used only within the range of the number of I/O points (the number of points that can
access I/O modules).
Ladder ST
ENO:=SPD(EN,s1,s2,d);
FBD/LD
Instruction Execution condition
SPD
Operand Description Range Data type Data type (label)
(s1) Pulse input device number Bit ANY_BOOL
*1
(s2) Measurement time, or the device number of the device
containing the measurement time (unit: ms)
-32768 to 32767 16-bit signed binary ANY16
(d) Device for storing the measurement result 16-bit signed binary ANY16
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
Operand Bit Word Double word Indirect
specification
Constant Others
X, Y, M, L,
SM, F, B, SB,
FX, FY
J\ T, ST, C, D, W,
SD, SW, FD, R,
ZR, RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K, H E $
(s1)
*1

(s2) 
(d) 
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(s1) (s2) (d)
EN ENO
ds1
s2