25 TYPE CONVERSION FUNCTIONS
25.5 Converting BOOL to TIME
1797
25
25.5 Converting BOOL to TIME
BOOL_TO_TIME(_E)
These functions convert a value from BOOL data type to TIME data type.
Setting data
Description, type, data type
Processing details
Operation processing
These functions convert the value input to (s) from BOOL data type to TIME data type, and output the converted value from
(d).
When the input value is FALSE, 0 (TIME data type) is output.
When the value is TRUE, 1 (TIME data type) is output.
Input a BOOL data type value to (s).
Operation result
1. Function without EN/ENO
The operation processing is performed. The operation result is output from (d).
2. Function with EN/ENO
The execution conditions and operation results will be as follows.
*1 If the value FALSE is output from ENO, the output data from (d) will be undefined. Create a program so that the undefined value will not
be used in operations.
Operation error
There is no operation error.
Ladder, FBD/LD Structured text
[Without EN/ENO] [With EN/ENO] [Without EN/ENO]
d:=BOOL_TO_TIME(s);
[With EN/ENO]
d:=BOOL_TO_TIME_E(EN,ENO,s);
Argument Description Type Data type
EN Execution condition (TRUE: Executed, FALSE: Not executed) Input variable BOOL
s (IN) Input Input variable BOOL
ENO Output status (TRUE: Normal, FALSE: Abnormal or operation stop) Output variable BOOL
d Output Output variable TIME
Execution condition Operation result
EN ENO (d)
TRUE (executed) TRUE Operation result output value
FALSE (not executed) FALSE
*1
Undefined value
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
sd
EN ENO
ds
(s)
(d)
T#0ms
T#1ms
FALSE
TRUE
TIMEBOOL