1350
11 PROCESS CONTROL INSTRUCTIONS
11.4 Correction Operation Instructions
11.4 Correction Operation Instructions
Function generator
S.FG
This instruction outputs the input data values following the specified function generator pattern.
Execution condition
Setting data
Description, range, data type
Applicable devices
Ladder ST
ENO:=S_FG(EN,s1,s2,d1,d2);
FBD/LD
Instruction Execution condition
S.FG
Operand Description Range Data type
(s1) Input data start device Refer to "Input data". Single-precision real
number
(d1) Block memory start device Refer to "Block memory". Single-precision real
number
(s2) Operation constant start device Refer to "Operation constant". 16-bit unsigned binary
(d2) Local work memory start device Refer to "Local work memory". Word
EN Execution condition Bit
ENO Execution result Bit
Operand Bit Word Double word Indirect
specification
Constant Others
X, Y, M, L,
SM, F, B, SB,
FX, FY
J\ T, ST, C, D, W,
SD, SW, R, ZR,
RD
U\G, J\,
U3E\(H)G
Z LT, LST,
LC
LZ K, H E $
(s1)  
(d1) 
(s2)  
(d2) 
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(s1) (d1) (s2) (d2)
EN ENO
d1
d2
s1
s2