19 CC-LINK INSTRUCTIONS
19.4 Writing Data to the Buffer Memory of the Specified Intelligent Device Station
19.4 Writing Data to the Buffer Memory of the Specified
Intelligent Device Station
G(P).RISEND
These instructions automatically perform handshake with the specified intelligent device station and writes data to its buffer
memory. The instructions can be used for communications with a module supporting a handshake signal such as AJ65BT-
R2N.
■Execution condition
■Description, range, data type
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
Ladder ST
ENO:=G_RISEND(EN,U,s1,s2,s3,d);
ENO:=GP_RISEND(EN,U,s1,s2,s3,d);
FBD/LD
Instruction Execution condition
G.RISEND
GP.RISEND
Operand Description Range Data type Data type (label)
(U) Start I/O number (first three digits in four-digit
hexadecimal representation) of a module
00H to FEH 16-bit unsigned binary ANY16
(s1) Start device where control data is stored Refer to the control data. Device name ANY16
*1
(s2) Start device for storing the data to be written Device name ANY16
*1
(s3) Start device for storing the interlock signal Device name ANY16
*1
(d) Device that turns on for one scan upon completion of the
instruction
When the instruction completes with an error, (d)+1 also
turns on.
Bit ANYBIT_ARRAY
(Number of elements: 2)
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)