18 CC-LINK IE FIELD NETWORK INSTRUCTIONS
18.5 Reading the Module Model Information of an Intelligent Device Station
18.5 Reading the Module Model Information of an
Intelligent Device Station
J(P).SINFTYRD, G(P)SINFTYRD
These instructions read the model names of modules and units used in an intelligent device station.
Execution condition
Setting data
Description, range, data type
*1 When specifying setting data by using a label, define an array to secure enough operation area and specify an element of the array
label.
The RnENCPU (network part), RJ71GF11-T2, and RJ71EN71 with firmware version "12" or later support these instructions. (Use an engineering tool with
version "1.025B" or later.)
Ladder ST
ENO:=J_SINFTYRD(EN,J,s,d1,d2);
ENO:=JP_SINFTYRD(EN,J,s,d1,d2);
ENO:=G_SINFTYRD(EN,U,s,d1,d2);
ENO:=GP_SINFTYRD(EN,U,s,d1,d2);
FBD/LD
Instruction Execution condition
J.SINFTYRD
G.SINFTYRD
JP.SINFTYRD
GP.SINFTYRD
Operand Description Range Data type Data type (label)
(J/
U)
J(P).SINFT
YRD
(J): Own station network number 1 to 239 16-bit unsigned binary ANY16
G(P).SINFT
YRD
(U): Start I/O number (first three digits in four-digit
hexadecimal representation) of own station or own
node
00H to FEH 16-bit unsigned binary ANY16
(s) Start device of the own station where control data is
stored
Refer to the control data. Device name ANY16
*1
(d1) Start device of the own station for storing the read
data (A continuous area of 890 words is required.)
Device name ANY16
*1
(d2) Device of the own station, which turns on for one
scan upon completion of the instruction.
When the instruction completes with an error, (d2)+1
also turns on.
Bit ANYBIT_ARRAY
(Number of elements:
2)
EN Execution condition Bit BOOL
ENO Execution result Bit BOOL
RnCPU
RnENCPU
RnSFCPU RnSFCPURnPCPURnPCPU
(Standard) (Safety)
(Redundant)
(Process)
(s) (d1) (d2)(J/U)
EN ENO
d1
d2
J/U
s